Surface
Monitoring - ISO 14644, Fed Std-209E,
USP <1116>
Contact plates filled with media are used to sample
tabletops, walls, benches, floors, garments, and
gowned personnel to measure the number of microorganisms
per area sampled. The media contains a neutralizer
which inactivates cleaning and disinfection solutions
to ensure that any microorganisms present are
not inhibited from growing. The plates are incubated
to promote growth, the microorganisms are enumerated
and results are reported as the number of CFU
(colony forming units) per area sampled.
| Test
Code |
Test
Description |
| EN-001 |
Incubation & enumeration
of contact plates |
| EN-007 |
Media - Surface Sampling |
|